Tuesday, November 29 | 9:30 a.m.-10:30 a.m. | T3-SSPH07-4 | Room S402
In this session, photon-counting CT (PCCT)'s potential in breast imaging will be discussed, with research suggesting it has similar image quality to dedicated breast CT.Stefan Sawall, PhD, from the German Cancer Research Center in Heidelberg will discuss findings on PCCT as a newcomer in breast screening. Sawall and colleagues used breast and thorax phantoms to represent realistic patient positioning. PCCT dose levels varied between 7 mGy and 25 mGy (CT dose index volume [CTDIvol]) at 120 kV in ultrahigh resolution mode. Meanwhile, images for dedicated CT were obtained using a standard protocol with a dose of 7 mGy (CTDIvol) at 49 kV.
The researchers wanted to compare the two methods by evaluating contrast-to-noise ratio of masses, the noise power spectrum, and the structural visibility of fibers and calcifications. They found that the contrast-to-noise ratio between masses and background was 1.3 on average when only using the breast phantom. Including the thorax phantom though, these differences varied between 0.9 to 2.3 mGy.
The researchers also found that the noise power spectrum's peak frequency in PCCT was 0.45 mm-1 compared with 0.40 mm-1 in dedicated breast CT. Additionally, calcifications down to a size of 0.29 mm and fibers down to a size of 0.23 mm could be identified in both systems' respective images.
Sawall et al suggested that PCCT could become an alternative to dedicated breast CT by providing additional information, such as identification of sentinel lymph nodes. They called for more studies on dosage delivered to other organs.
Find out more in Sawall's presentation.












![Images show the pectoralis muscles of a healthy male individual who never smoked (age, 66 years; height, 178 cm; body mass index [BMI, calculated as weight in kilograms divided by height in meters squared], 28.4; number of cigarette pack-years, 0; forced expiratory volume in 1 second [FEV1], 97.6% predicted; FEV1: forced vital capacity [FVC] ratio, 0.71; pectoralis muscle area [PMA], 59.4 cm2; pectoralis muscle volume [PMV], 764 cm3) and a male individual with a smoking history and chronic obstructive pulmonary disorder (COPD) (age, 66 years; height, 178 cm; BMI, 27.5; number of cigarette pack-years, 43.2, FEV1, 48% predicted; FEV1:FVC, 0.56; PMA, 35 cm2; PMV, 480.8 cm3) from the Canadian Cohort Obstructive Lung Disease (i.e., CanCOLD) study. The CT image is shown in the axial plane. The PMV is automatically extracted using the developed deep learning model and overlayed onto the lungs for visual clarity.](https://img.auntminnie.com/mindful/smg/workspaces/default/uploads/2026/03/genkin.25LqljVF0y.jpg?auto=format%2Ccompress&crop=focalpoint&fit=crop&h=112&q=70&w=112)