Monday, December 2 | 3:30 p.m.-3:40 p.m. | SSE02-04 | Room E450A
Breast tomosynthesis performs particularly well at visualizing noncalcification breast cancers in patients who are in the middle of the dense tissue spectrum, Connecticut researchers have found.Dr. Reni Butler, from Yale School of Medicine, and colleagues reviewed 155 breast cancers diagnosed between October 2011 and January 2013 that were imaged with tomosynthesis in combination with 2D mammography. Seven breast radiologists evaluated the images, classifying them into five categories:
- Only seen on tomosynthesis
- Better seen on tomosynthesis
- Equally well seen on both modalities
- Better seen on mammography
- Only seen on mammography
The reading radiologists also recorded breast density, type of mammographic finding, clinical presentation, and cancer histology for each case.
Butler and colleagues found that women in the middle of the breast tissue density continuum had the highest percentage of cancers seen only on or better with tomosynthesis, with a rate of 67.7% for scattered fibroglandular tissue and 69.8%% for heterogeneously dense tissue. Tomosynthesis alone visualized only 5.9% of cancers in patients with extremely dense breasts and 0% in patients with fatty breast tissue.
Patients with fatty breasts and extremely dense breasts had the most cancers seen equally well on either modality, at 86.7% and 58.8%, respectively. As tomosynthesis becomes more widely used, it's crucial for radiologists to understand its relative benefit in different groups of patients, Butler's group concluded.














![A normal mammogram confirmed by three-year radiologic follow-up illustrates reader-marked regions of interest (ROIs) during (A) unaided (round 1) and (B) artificial intelligence (AI)–assisted (round 2) reading. Each colored dot represents an ROI for recall by a human reader. Readers could mark more than one ROI per case, represented by multiple dots of the same color. During AI-assisted reading, the AI system displayed three visible prompts: two with suspicion of malignancy scores of 35% (left mediolateral oblique [L MLO] and craniocaudal [L CC]) and one with a suspicion of malignancy score of 10% (right craniocaudal [R CC]), shown as polygonal overlays. Without AI, six of 10 readers (60%) marked a false-positive ROI. With AI assistance, this fell to two of 10 (20%). R MLO = right mediolateral oblique.](https://img.auntminnie.com/mindful/smg/workspaces/default/uploads/2026/07/2026-07-14-radiology-mammogram-ai-auto-bias.H0bYO8QlWs.jpg?auto=format%2Ccompress&fit=crop&h=112&q=70&w=112)