Monday, November 26 | 3:30 p.m.-3:40 p.m. | SSE02-04 | Room E450A
Using digital breast tomosynthesis (DBT) as an adjunct to mammography lowers recall rates, according to this Monday afternoon scientific session.Dr. Brian Haas, from Yale University, and colleagues included all patients who presented for screening mammograms between October 2011 and March 2012 at four clinical sites, one of which has a DBT unit. Patients at this site were offered screening with DBT as well as conventional digital mammography, while patients at the other three sites had digital mammography alone.
Of 5,780 patients, 1,602 received DBT. Haas' group found that the overall recall rate for patients in the tomosynthesis group was 7%, compared with 10.9% for conventional imaging alone. This reduction in recall rates ran across all tissue density and age groups, with significant differences in women with heterogeneously dense breasts (7.7% versus 14.8%), those with extremely dense breasts (2.2% versus 17.1%), and women younger than 40 (4.1% versus 20.5%).
DBT's overall cancer detection rate was 5.6 per 1,000, while conventional digital mammography's rate was 3.4 per 1,000, leading the team to conclude that DBT promises to have a powerful effect on screening mammography.









![A normal mammogram confirmed by three-year radiologic follow-up illustrates reader-marked regions of interest (ROIs) during (A) unaided (round 1) and (B) artificial intelligence (AI)–assisted (round 2) reading. Each colored dot represents an ROI for recall by a human reader. Readers could mark more than one ROI per case, represented by multiple dots of the same color. During AI-assisted reading, the AI system displayed three visible prompts: two with suspicion of malignancy scores of 35% (left mediolateral oblique [L MLO] and craniocaudal [L CC]) and one with a suspicion of malignancy score of 10% (right craniocaudal [R CC]), shown as polygonal overlays. Without AI, six of 10 readers (60%) marked a false-positive ROI. With AI assistance, this fell to two of 10 (20%). R MLO = right mediolateral oblique.](https://img.auntminnie.com/mindful/smg/workspaces/default/uploads/2026/07/2026-07-14-radiology-mammogram-ai-auto-bias.H0bYO8QlWs.jpg?auto=format%2Ccompress&fit=crop&h=112&q=70&w=112)