Musculoskeletal > Lymph

J Nucl Med 2001 Aug;42(8):1198-215

Radioguided sentinel lymph node biopsy in breast cancer surgery.

Mariani G, Moresco L, Viale G, Villa G, Bagnasco M, Canavese G, Buscombe J, Strauss HW, Paganelli G.

The concept of sentinel lymph node biopsy in breast cancer surgery relates to the fact that the tumor drains in a logical way through the lymphatic system, from the first to upper levels. Therefore, the first lymph node met (the sentinel node) will most likely be the first to be affected by metastasis, and a negative sentinel node makes it highly unlikely that other nodes are affected. Because axillary node dissection does not improve prognosis of patients with breast cancer (being important only to stage the axilla), sentinel lymph node biopsy might replace complete axillary dissection to stage the axilla in clinically N0 patients. Sentinel lymph node biopsy would represent a significant advantage as a minimally invasive procedure, considering that, after surgery, about 70% of patients are found to be free from metastatic disease, yet axillary node dissection can lead to significant morbidity. Furthermore, histologic sampling errors can be reduced if a single (sentinel) node is assessed extensively rather than few histologic sections in a high number of lymph nodes per patient. Although the pattern of lymph drainage from breast cancer can be variable, the mammary gland and the overlying skin can be considered as a biologic unit in which lymphatics tend to follow the vasculature. Therefore, considering that tumor lymphatics are disorganized and relatively ineffective, subdermal and peritumoral injection of small aliquots of radiotracer is preferred to intratumoral administration. (99m)Tc-labeled colloids with most of the particles in the 100- to 200-nm size range would be ideal for radioguided sentinel node biopsy in breast cancer. Lymphoscintigraphy is an essential part of radioguided sentinel lymph node biopsy because images are used to direct the surgeon to the site of the node. The sentinel lymph node should have a significantly higher count than that of background (at least 10:1 intraoperatively). After removal of the sentinel node, the axilla must be reexamined to ensure that all radioactive sites are identified and removed for analysis. The sentinel lymph node should be processed for intraoperative frozen section examination in its entirety, based on conventional histopathology and, when needed, immune staining with anticytokeratin antibody. The success rate of radioguidance in localizing the sentinel lymph node in breast cancer surgery is about 94%--97% in institutions where a high number of procedures are performed and approaches 99% when combined with the vital blue dye technique. At present, there is no definite evidence that negative sentinel lymph node biopsy is invariably correlated with negative axillary status, except perhaps for T1a-b breast cancers, with a size of < or =1 cm. Randomized clinical trials should elucidate the impact of avoiding axillary node dissection on patients with a negative sentinel lymph node on the long-term clinical outcome of patients.

Latest in Musculoskeletal
More in Musculoskeletal
Page 1 of 6
Next Page