Aortic wall compliance useful in evaluating AAA risk noninvasively

Wall compliance and stiffness measurement may be useful in evaluating the success of endovascular repair for abdominal aortic aneurysms (AAA), according to a study by U.K. researchers.

The ultrasound study, done in 57 patients to assess aortic wall compliance as an indicator for rupture risk in AAA, also concluded that endovascular repair (EVR) leaves patients with greater wall stiffness than those undergoing open surgical repair.

"Postrepair compliance is influenced by actual wall stiffness, intraluminal or intrasac pressure, pulse pressure, and also the type of stent (balloon or self-expandable) and the effect of the thrombus," said Dr. Amine Sekhri, who presented the study findings at the 2004 RSNA conference in Chicago. Sekhri's group is from the medical imaging and endovascular units of The Middlesex Hospital and University College London Hospitals in London.

The study consisted of 29 subjects in the prerepair group and 32 in the postrepair group. Eight patients were in both groups. The mean patient age was 78 years. Of the 32 patients in the postrepair group, 26 underwent endovascular repair and six had open surgical repair. There were endoleaks or endotension in eight patients with EVR. The rest had no complications.

Ultrasound was done using a HDI 5000 scanner (Philips Medical Systems, Andover, MA). The cine-loop images were analyzed offsite to measure the aortic diameter during systole and diastole using wall-tracking software, HDILab (ATL, Bothwell, WA).

Brachial blood pressure was measured, and elastic modulus (Ep) and stiffness (β) calculated. Ep and β were calculated at the neck of the aneurysm, inflection points, and midsac levels. "Patients with endoleaks had significantly elevated Ep and ß compared with those without endoleaks," the researchers stated.

According to previous research, Ep and β have an inverse relationship with aortic wall compliance. This allows a better estimate of AAA rupture risk than taking aneurysm size alone into consideration (European Journal of Vascular Endovascular Surgery, June 1998, Vol. 15:6; pp. 472-477).

Based on the preoperative and postoperative Ep and β results from the current study, Sekhri also observed that the compliance measurement agreed with wall stress distribution in AAA. And that maximum stress is not necessarily located in the maximum diameter.

Other studies to assess the risk of rupture have found wall stress to be distributed with distinct regions of high and low stress. Knowledge of this stress distribution will be a better indicator than going only by the diameter of the aneurysm (Journal of Vascular Surgery, April 2000, Vol. 31:4, pp. 760-769).

Aortic wall compliance measurement in AAA can detect the potential prerepair state of AAA and evaluate the success of EVR, with the advantage of being noninvasive and low-cost with ultrasound, Sekhri concluded.

By N. Shivapriya
AuntMinnie.com contributing writer
March 15, 2005

Related Reading

MRI for carotid artery wall thickness measures up to US gold standard, February 3, 2005

Older men should be screened for aortic aneurysm, February 1, 2005

New treatment for aortic aneurysm triggers debate, October 15, 2004

Copyright © 2005 AuntMinnie.com

Page 1 of 509
Next Page