Monday, November 30 | 8:00 a.m. to 9:00 a.m. | M1-SSPD02-6| Room E352
Here, researchers will report on the performance of four risk stratification systems in pediatric patients and the testing of modified strategies for TI-RADS tailored to children.
Ultrasound risk-stratification systems help decide which thyroid nodules need biopsy, but most were built for adults. Taewan Kim, MD, from Oswego Health will present his team’s study evaluating the diagnostic accuracy of TI-RADS, American Thyroid Association (ATA) guidance, K-TIRADS, and EU-TIRADS in pediatric patients.
The team evaluated 19 studies that covered 2,945 pediatric patients with 3,119 thyroid nodules, of which 36.4% were malignant. Pooled sensitivity and specificity were 75.4% and 69.7% for ACR TI-RADS, 85.6% and 18.7% for ATA, 84.7% and 59.2% for K-TIRADS, and 71.8% and 66.0% for EU-TIRADS.
TI-RADS had lower sensitivity than ATA (p = 0.04) and K-TIRADS (p = 0.002) but higher specificity than both (p < 0.001 and p = 0.03). ATA had the lowest specificity of all four systems.
Among modifications, removing the size threshold for TR5 nodules (from 10 mm) lowered specificity to 66.7% (p = 0.03). Raising the TR3 threshold from 25 mm to 35 mm raised specificity to 77.1%, which was not significantly different from the original 69.7% (p = 0.13).
Kim and colleagues suggest that lowering the biopsy size threshold for high-suspicion nodules while raising it for low-suspicion nodules may optimize performance in pediatric thyroid nodules.