Early F-18 MK-6240 tau PET scans feasible

Thursday, December 3 | 1:30 p.m.-2:30 p.m. | R6-SSNMMI08-4 | Room S405 

F-18 MK-6240 tau PET scans acquired at 40 to 60 minutes post-injection discriminate Alzheimer disease tau burden as accurately as standard 90- to 120-minute scans, according to research in this session. 

In a retrospective within-subject analysis, Tsung-Wei Hu, PhD, of Weill Cornell Medicine in New York City, and colleagues studied 67 participants across the Alzheimer disease (AD) spectrum: cognitively unimpaired, those with mild cognitive impairment (MCI), and those with AD. Participants underwent F-18 MK-6240 PET with both early (40 to 60 minutes) and late (90 to 120 minute) frames. Standard uptake value ratios (SUVR) were calculated in the cerebral cortex and Braak staging regions using cerebellar cortex as the reference. Skull and meningeal uptake was graded visually and quantified. 

Early and late SUVRs were highly correlated (r ≥ 0.97) with similar cohort-level distributions. Diagnostic performance was comparable: cortical AUC for distinguishing cognitively unimpaired participants from those with MCI or AD was 0.88 for early frames versus 0.85 for late. In tau-negative participants, skull SUVR exceeded entorhinal SUVR after approximately 60 minutes on late frames. Time-resolved analyses confirmed that later acquisition did not improve diagnostic discrimination and was associated with more extracerebral contamination. 

MK-6240 is a widely used second-generation tau PET tracer currently under FDA review, making it important to refine practical static imaging windows for clinical use, the researchers noted. Extracerebral skull and meningeal uptake becomes more prominent at later times and may confound visual interpretation and SUVR quantification, they added. 

“The 40-60-minute window provides discrimination comparable to 90-120 minutes while reducing extracerebral contamination and improving robustness, supporting shorter static F-18 MK-6240 protocols for clinical and research applications," the group wrote. 

Attend this session to learn more. 