Wednesday, December 2 | 3:00 p.m.- 4:00 p.m. | W7-SSPH11-6 | Room E351
16-cm wide-detector CT cuts patient radiation dose in the emergency department by 19% and scan time by 47.7% -- without compromising chest image quality, according to this scientific presentation.
The findings could translate to better care for patients with "respiratory cooperation difficulties," and could mitigate "the strict breath-holding requirements of traditional CT," presenter Zihan Zhang, MD, of Yichang Central People's Hospital in China, and colleagues noted.
Zhang's group performed a study that included data from 40 patients unable to cooperate with breath-holding instructions during chest CT; the patients were randomized into a control group of 20 who underwent an 8-cm conventional detector CT exam and an observation group of 20 who underwent a 16-cm wide-detector spiral CT scan. The researchers reconstructed the images using a deep-learning (DL) algorithm (ClearInfinity). They compared CT attenuation, image noise, signal-to-noise ratio, and contrast-to-noise ratio between the two types of exams.
Overall, Zhang and colleagues reported that patients who underwent 16-cm wide-detector spiral CT scans showed lower radiation doses compared to the control group, as well as lower dose length product, CTDIvol, and effective dose. The 16-cm wide-detector spiral CT exams reduced scan time by 47.7%.
"[16-cm wide-detector spiral CT imaging] provides an optimized imaging protocol for emergency patients with respiratory cooperation difficulties," the team concluded.