CT can replace x-ray for pediatric cystic fibrosis patients

CHICAGO - Ultralow-dose CT is on par with a frontal chest x-ray in terms of dose (0.05 mSv) and gives an accurate diagnosis in pediatric cystic fibrosis patients, Belgian researchers revealed on Monday afternoon at the annual RSNA meeting.

Radiation is always a concern when imaging a patient, but it's even more important for pediatric patients. A chest x-ray is typically used to assess cystic fibrosis, but the modality obviously doesn't offer the same amount of detail as a CT scan. Dr. Caroline Ernst, from University Ziekenhuis in Brussels, and colleagues sought to determine whether ultralow-dose CT could replace chest x-ray altogether for these patients.

In their prospective study, 22 patients underwent ultralow-dose CT. The scans were reconstructed with a model-based iterative reconstruction technique (Veo, GE Healthcare) and randomized and scored using the Bhalla CT scoring system by two radiologists. The ultralow-dose CT scores were compared with Bhalla scores of previous low-dose CT scans obtained in 2009 or 2010.

During her presentation, Ernst clarified that reconstruction is on the model. "It's not like adaptive statistical iterative reconstruction, it's a computer where you put in the information," she said. "We first lowered the dose and you have a lot of image noise, and it's a model that reconstructs images over and over again until an acceptable image [appears]."

The mean CT dose index volume (CTDIvol) for the ultralow-dose CT scans was 0.12 mGy, with a mean estimated effective dose of 0.05 mSv, Ernst said. The mean CTDIvol for the low-dose CT scans was 2.23 mGy, with a mean estimated effective dose of 1.01 mSv.

The mean Bhalla score for the ultralow-dose CT scans was 6.91, compared with 5.65 for the low-dose CT scans. No significant differences were found between the ultralow-dose and low-dose CT scans, Ernst said.

"Our results show that an ultralow-dose CT can be performed with an estimated effective dose of 0.05 mSv, which is in the range of anteroposterior chest dose, and that there is very good agreement in the overall Bhalla score and in the detection and extent of bronchiectasis," she said.

The results show ultralow-dose CT can be performed in pediatric cystic fibrosis patients at a radiation dose that approaches that of a frontal chest radiograph, and that ultralow-dose CT may replace chest x-ray in these patients for a more accurate assessment of bronchiectasis.

"This results in more accurate treatment, but of course more studies have to be done in larger patient groups," Ernst said.

Page 1 of 653
Next Page