GA-oriented morphology boosts fetal US malformation workup

2007 08 08 15 32 43 706

Incorporating gestational age (GA)-oriented morphology in biometry data could significantly increase the yield for ultrasound scanning of fetal malformations during the 6-16 weeks gestational age, according to research from the Ironfan-International Registry of Fetal Anomalies at Columbia University Medical Center in New York City.

"Time-oriented sonomorphology mapping is the most important component of the early malformation work-up. Fetal biometry has a minor impact," said Dr. Shraga Rottem of Columbia University at the 2007 American Institute of Ultrasound in Medicine (AIUM) meeting in New York City.

To investigate the potential effect of GA-oriented morphology mapping in addition to biometry in early malformation work-up, the Ironfan researchers began the study by utilizing personal experience, and calling for cases from 65 centers and practitioners worldwide of fetal anomalies, organs, and development charts detected during a 4-16 week sonogram.

They developed three comprehensive 4-16 weeks time-oriented databases, including a 4-16 weeks fetal anatomy and physiology database, a 6-16 weeks anomalies database, and a 4-16 weeks biometry database. As determined by ultrasound throughout pregnancy, fetal anomalies were classified into four classes:

  • Type I: Early onset at constant gestational age
  • Type II: Transient condition
  • Type III: Variable onset or potentially unstable anomalies
  • Type IV: Late onset anomalies

Using a specially designed time-oriented program, the researchers analyzed the 4-16 weeks database to determine the relative contributions of biometry and morphology-dysmorphology at the detection of a fetal anomaly at the earliest time of diagnosis between 6-16 weeks.

"We looked at the data and it was immediately obvious that morphology is what piqued the eye of the operator -- and not what came out from the US machine, which was the biometry," Rottem told AuntMinnie.com. "So here we have a situation where what comes from the routine scan from the machine has little contribution."

These conclusions were confirmed by a review of the literature, Rottem said.

"The literature confirmed our initial finding that the observation of morphology from the operator is much more important than what comes out from the data during the sonogram," he said.

Based on their own findings as well as literature review, the researchers determined that 161 organs, structures, and areas were detectable during a 4-16 weeks sonogram. In addition, 379 different types of fetal abnormalities may be detected at a 6-16 weeks sonogram, according to Rottem.

In 292 of the 379 (77%) types of fetal malformations studied, the 6-16 weeks malformation workup was based on morphology information alone, according to the researchers. Relying on biometry by itself was useful in only 87 anomalies (23%) of the cases.

The yield from combining morphology information and biometry is significantly increased for Type I anomalies, Rottem said. In addition, it was particularly useful in musculoskeletal and cardio/thorax malformations.

Rottem envisions a next generation of ob/gyn ultrasound systems that could move from malformation workup using fetal biometry charts to an approach that combines a early, time-oriented fetal sonomorphology system with results of normal or abnormal biometry.

This could be accomplished using Ironfan's database, linked to fetal biometry info and the ultrasound scanner, Rottem said.

2007 08 08 15 32 43 706
The Ironfan Society's concept of incorporating a morphological system with biometry data to assist in time-oriented early fetal ultrasound scanning for malformations. Image courtesy of Dr. Shraga Rottem.

A field test is currently being organized to link ultrasound machines with Ironfan's database, providing automatic feedback to the operator without user intervention, he said.

Ironfan would be interested in offering ultrasound vendors a link to the database for all its users, Rottem said.

"Our goal is to open this service via license to all the OEMs," he said. "This will allow the linking of their community of users and ultrasound systems to the database."

By Erik L. Ridley
AuntMinnie.com staff writer
August 9, 2007

Related Reading

Fetal entertainment ultrasounds draw patient interest, March 20, 2007

Early prenatal ultrasound inadequate for detecting congenital heart malformations, June 30, 2006

Empty renal fossa on prenatal ultrasound indicates renal ectopia or agenesis, August 17, 2005

Fetal ear length may indicate chromosomal abnormality, April 11, 2002

Multinational study makes case for first-trimester sonography, June 12, 2001

Copyright © 2007 AuntMinnie.com

Page 1 of 507
Next Page